Christopher,

I suspect you mean /30 addresses /31 would allow only network and
broadcast addresses, with no room for hosts. :)

I am currently sunning HA CAMs. I have tested HA CASs with /30 network
and they work fine. I am awaiting my NIC cards to implement HA CASs.


Bruce Osborne
Liberty University

-----Original Message-----
From: Cisco Clean Access Users and Administrators
[mailto:[log in to unmask]] On Behalf Of Christopher Chin
Sent: Friday, June 22, 2007 12:37 PM
To: [log in to unmask]
Subject: [CLEANACCESS] network settings for HA udp heartbeat

Hello there,

We're running a pair of appliance CASes in HA mode, and just
installed an additional interface card so that we can run
our udp heartbeat over eth2 instead of over the
trusted/management interface.

Has anyone tried to run this with /31 addresses?

Thanks,
 - Christopher

======================